Dynalene Fluid Care Program

Complete Care — From Specification Assurance at Commissioning to Multi-Year Protection

Overview

Dynalene Fluid Care Program

Free Specification Assurance at Commissioning for 5k+ gal orders—we provide comprehensive testing and support to ensure your fluid is within spec.

Included (First 90 Days)

Proactive annual fluid care with automatic sample kits and routine testing—free for 5 years on >5,000 gal data center coolant orders (up to 4 Basic & Advanced tests/yr).

Included (Per Loop / Year)

Single-sample testing for routine checkups (Basic) or root-cause diagnostics (Advanced) for your application.

Tests Included by Level

In mission-critical cooling loops—from AI data centers and EV/fuel cell systems to industrial chillers and process reactors—unmonitored fluid degradation, inhibitor depletion, or contamination can trigger corrosion, fouling, premature fluid change-outs, and costly unplanned downtime.

Proven since the early 2000s, the Dynalene Fluid Care Program protects your system at every stage—including an industry-first commitment for data centers offering free 90-day Dynalene Promise commissioning assurance and free 5-year Dynalene Protect coverage (up to 4 Basic & Advanced tests/yr) on data center coolant orders greater than 5,000 gallons. Whether through Dynalene Promise, Dynalene Protect, or Dynalene On-Demand testing, samples are analyzed in-house at Dynalene Labs by the same chemists and engineers who formulated your fluid—and who prescribe the exact glycol/booster adjustment or in-line Ion Exchange, Filtration, or Desiccation hardware to restore performance.

Step-by-Step Process

How the Dynalene Fluid Care Program Works

From Commissioning to Continuous Annual Protection

From commissioning under Dynalene Promise to annual maintenance with Dynalene Protect, every step is handled by a single company.

01

Spec Assurance at Commissioning:

Unlimited Basic & Advanced testing and tech support for 90 days until verified in-spec.

02

Auto Kit Mailing, Collect & Send Samples

Receive scheduled 100 mL kits (with SDS), draw a sample, and mail it back.

03

In-House Lab Testing:

Dynalene performs all routine Basic & Advanced testing for your application.

04

Report, Trending & Consult:

Lab report, online trend analysis, and engineering support.

05

Prescribed Remediation:

Apply booster dosing or in-line filtration hardware.

Pre-Labeled 100 mL Sampling Kit

Every scheduled Dynalene Protect test and On-Demand order ships with a complete, ready-to-use 100 mL fluid sampling kit—just draw a sample, seal, and drop it in the mail:

Recommended Sampling & Testing Schedule by Application Tier

Application / Lifecycle Stage Program Testing Frequency Engineering Purpose
1. New Bulk Loop Commissioning for All Applications Dynalene Promise Unlimited (as needed) Sets initial baseline and validates that bulk loops start in-spec.
2. Direct-to-Chip (DTC) AI Data Centers Dynalene Protect Quarterly (Up to 4/yr) Meets OCP PG25 guidelines and protects microchannel copper cold plates. Free for 5 yrs on >5,000 gal data center coolant orders (up to 4 Basic & Adv. tests/yr).
3. EV Battery, Fuel Cell & Low-Conductivity Loops Dynalene Protect Semi-Annually Tracks ionic leachates and guides Ion Exchange cartridge replacement.
4. Industrial Chiller & Process Loops Dynalene Protect Semi-Annually Maintains freeze protection, reserve alkalinity, and corrosion inhibition.

Videos

See It In Action

Watch product overviews, installation walkthroughs, and real-world application demonstrations for Dynalene ion exchange systems.

IC Series Product Overview

Cartridge Installation & Replacement Guide

DYI Series: On-Site DI Water Generation

Where It Works

Use Cases

USE CASE 01 · AI DATA CENTER COMMISSIONING

5-Day Commissioning of a Mission-Critical 120,000-Gal AI Data Center Loop

The Challenge: During startup of a mission-critical 120,000-gal DTC AI data center loop, residual flush water and variable incoming water quality pushed conductivity and copper above OCP PG25 limits.

Startup Cleanup (5 Days) & 90-Day Monitoring (ppm Cu)

With Dynalene Promise

USE CASE 02 · INDUSTRIAL CHILLERS & PROCESS LOOPS

6+ Years of Zero-Drain Operation in an Industrial Process Glycol Loop

The Challenge: Continuous thermal cycling and make-up water additions in a 15,000-gal industrial chiller loop gradually dilute freeze protection and consume corrosion inhibitors.

Fluid pH & Inhibitor Health — 6-Year Dynalene Protect

With Dynalene Protect

Multi-Year Trend Example · Dynalene Protect Online Trend Analysis

How Fluid Parameters Change Annually — Monitored vs. Unmonitored Loop

With Dynalene Protect (Proactive Fix) Unmonitored Loop ("Fill-and-Forget") Target Specification Zone

Program Benefits

Key Benefits of the Program

Verified In-Spec Commissioning

Dynalene Promise provides baseline verification, unlimited testing, and 90-day support until bulk loops are in-spec

Prevent Unplanned System Downtime

A 100 mL checkup catches inhibitor depletion, dilution, or contamination months before equipment is damaged.

Extend Fluid Life Without Draining

Skip costly drain-and-refills and disposal fees—restore fluid online with inhibitor boosters or in-line cleaning hardware.

Cut Chiller & Pumping Energy Bills

On-spec fluid concentration and clean heat transfer surfaces prevent fouling and reduce power consumption.

Dedicated Support & Exact Fixes

Instead of raw lab numbers, get a dedicated specialist, result consultations, and the exact remediation fix.

Automated Kits & Online Tracking

Dynalene Protect ships kits automatically and tracks multi-year trends online to document OEM warranty compliance.

Laboratory Capabilities

Dynalene Laboratory & Analytical Capabilities

30+ years of thermal fluid R&D and wide-spectrum analytical testing from a single ISO 9001 company.

Thermal & Physical Analysis

  • Thermal conductivity & flash point
  • Differential scanning calorimetry (DSC)
  • Thermogravimetric analysis (TGA)
  • Rheometry & viscometry

Chemical Analysis

  • Gas chromatography–MS (GC-MS)
  • Liquid chromatography (HPLC)
  • Infrared spectroscopy (FTIR)
  • UV-Vis spectrophotometry

Microscopy Analysis

  • Scanning electron microscopy (SEM)
  • Energy dispersive X-ray (EDS)
  • Optical microscopy
  • Scale & particulate analysis

Corrosion & Fluid Health

  • Electrochemical corrosion testing
  • Multi-metal & elastomer compatibility
  • Accelerated thermal aging
  • In-service fluid & resin diagnostics
Chemical Analysis
Microscopy
Thermal Analysis

Why Dynalene

Integrated Fluid, Lab & Hardware Partner

Dynalene manufactures the heat transfer fluid, operates the analytical laboratory, and engineers the in-line filtration hardware—all from a single company.

One Partner, Zero Finger-Pointing

Fluid chemistry, lab diagnostics, inhibitor boosters, and filtration hardware backed by a single manufacturer.

In-House Dynalene Labs

Samples analyzed directly by the chemists who formulated your fluid—not a generic third-party lab.

30+ Years of HTF Expertise

Three decades solving thermal fluid challenges—with our Fluid Care Program operating since the early 2000s.

Matched In-Line Hardware

Custom Ion Exchange, Filtration, and Desiccation systems engineered to restore fluid online.

3 ISO 9001 U.S. Facilities

Nationwide production and rapid support from Whitehall, PA, Wood Dale, IL, and Salt Lake City, UT.

Day-One to Multi-Year Protection

90-day commissioning assurance (Dynalene Promise) and automated annual protection (Dynalene Protect) with a single point of contact.

Get Started

How Can We Help?

Dynalene Promise & Protect

Commissioning a 5k+ gal bulk loop or enrolling in annual Dynalene Protect? Get automated kits, routine testing, and dedicated support.

Order Kit & Test

Need an on-demand checkup? Order a pre-labeled 100 mL sampling kit for Basic or Advanced diagnostics at Dynalene Labs.

Talk to an Engineer

Discuss fluid test results, inhibitor boosters, or in-line Ion Exchange, Filtration, and Desiccation hardware with our engineers.

Type here to search

Order Kit & Test

Pre-labeled 100 mL Sampling Kit (with SDS) from Dynalene Labs

Kit Includes: Leak-proof 100 mL sample bottle, branded return mailer box with absorbent pouch, SDS & chain-of-custody card, and prepaid return shipping label. Placeholder Image and Text

Great! We’ve received your request.

Program Inquiry

Dynalene Promise, Dynalene Protect & On-Demand Testing

Great! We’ve received your request.

Program Inquiry

Dynalene Promise, Dynalene Protect & On-Demand Testing

Great! We’ve received your request.

Dynalene Labs · Whitehall, PA

Example Basic Fluid Analysis Report

Fluid: Dynalene PG (40% Vol)  |  Sample Volume: 100 mL  |  Status: PASS — Healthy
Test Parameter ASTM / Method Sample Result Target Specification Assessment
Appearance Visual Inspection Clear, fluorescent yellow, free of sediment Clear, free of suspended solids Normal
Fluid Concentration (Density & Refractive Index) ASTM D3321 / D5931 39.5% Volume PG (Freeze Pt: -21°C / -6°F) 40.0% ± 2.0% Volume Within Spec
pH Level (25°C) ASTM D1287 9.1 8.5 – 10.0 Optimal
Electrical Conductivity Conductivity Meter 2.84 mS/cm 2.50 – 3.50 mS/cm Normal
Inhibitor Package Health (Reserve Alkalinity) ASTM D1121 11.8 mL (96% active inhibitor remaining) ≥ 9.0 mL Passivated

Dynalene Engineering Recommendation: Fluid concentration, pH, conductivity, and corrosion inhibitor levels are all within optimal specification. No glycol adjustment or re-inhibition required at this time. Next routine Basic Testing checkup recommended in 6 months (semi-annual schedule)

Dynalene Labs · Whitehall, PA

Example Advanced Fluid Analysis Report

Fluid: Dynalene PG (35% Vol)  |  Sample Volume: 100 mL  |  Status: ACTION REQUIRED — Remediation Recommended
Diagnostic Category Analytes Measured (ppm) Sample Results (ppm) Assessment
Corrosion Products (ICP-OES) Fe, Al, Cu, Pb, Sn, Ag, Zn Fe: 18.4 ppm, Cu: 6.2 ppm, Al/Pb/Sn/Ag/Zn: < 0.5 ppm Elevated Fe & Cu
Contaminants (IC / ICP) Ca, Mg, Si, B, Mo, Na, SO₄²⁻, Cl⁻, NO₃⁻ Cl⁻: 92 ppm, Ca: 28 ppm, Mg: 9 ppm, SO₄²⁻: 34 ppm Hard Make-Up Water Ingress
Glycol Breakdown Products (IC) Glycolate, Formate, Acetate, Oxalate Glycolate: 310 ppm, Formate: 85 ppm, Acetate: 22 ppm, Oxalate: < 5 ppm Moderate Thermal Oxidation

Dynalene Engineering Recommendation: Elevated chloride (92 ppm) and hardness ions indicate un-deionized make-up water top-offs, while glycolate/formate organic acids have begun consuming reserve alkalinity and mobilizing iron/copper. Proactive Fix: Install an in-line / side-stream Dynalene CRS Series Ion Exchange unit with DYS 5 µm Filtration to strip chlorides and organic acids, then dose with custom Dynalene PG Inhibitor Booster.

Pre-Labeled 100 mL Sampling Kit: Includes a leak-proof 100 mL sample bottle, branded return mailer box with absorbent pouch, SDS & chain-of-custody card, and prepaid return shipping label.

Talk to an Engineer

Discuss test results, inhibitor boosters & in-line hardware

Great! We’ve received your request.

Submit Fluid Sample

Send your coolant sample to Dynalene Labs

Great! We’ve received your request.

⚙️ Talk to an Engineer

Custom solutions for your application

Great! We’ve received your request.

⚡ Quick Quote

We'll respond as soon as possible

Great! We’ve received your request.