Open Bath Fluids

Dynalene offers a wide selection of heat transfer fluids for quench and open bath cooling and heating applications in a temperature range from 550°F (288°C) to below -60°F (-51°C). Each Dynalene product listed below is engineered for consistently safe, odor-less operation, even in the most difficult thermal transfer processes, when used in properly designed systems.

Please feel free to contact Dynalene for more information on open bath and quench heating and cooling application heat transfer fluids. Substantial discounts are available in 55 gallon and bulk containers. All open bath applications should be approved by Dynalene’s engineering department prior to use.

Dynalene HC-50

Dynalene HC/Potassium Formate is a water-based, low-temperature heat transfer fluid engineered to deliver excellent heat transfer performance in applications down to -58°F (-50°C). With a temperature range from -50°C to +218°C, Dynalene HC easily exceeds the performance of other water-based chemistries such as glycol/water mixtures and calcium chloride solutions, as well as hydrocarbon- and silicone-based fluids. This fluid comes in five concentrations and is non-toxic, non-hazardous and non-flammable. Custom formulations are available upon request.

Dynalene “LO” Series

Dynalene “LO” series Heat Transfer Fluids for open bath applications are specifically engineered to offer food grade toxicity ratings and non-noxious odor characteristics without jeopardizing thermal efficiency. Dynalene “LO” series fluids including the products, Dynalene HF-LO, Dynalene LO-170 and Dynalene LO-230, consistently provide high-level environmental and workplace friendly performance to maintain the high safety and efficiency expectations of the customer.

Dynalene HF-LO Heat transfer fluids

  • Recommended Temperature Range: -52°C to 58°C (-60°F to 135°F)
  • Vapor Pressure: Negligible @ 0°C (32°F); <0.02 psia @ 20°C (68°F)
  • Boiling Point: >191°C (>376°F)
  • Flash Point: >61°C (>141°F)

Dynalene LO-170 Heat Transfer Fluids

  • Recommended Temperature Range: -40°C to 74°C (-40°F to 165°F)
  • Vapor Pressure: Negligible @ 0°C (32°F); <0.02 psia @ 50°C (122°F)
  • Boiling Point: >223°C (>433°F)
  • Flash Point: >77°C (>170°F)

Dynalene LO-230 heat transfer fluids

  • Recommended Temperature Range: 0°C to 110°C (32°F to 230°F)
  • Vapor Pressure: Negligible @ 0°C (32°F); <0.02 psia @ 100°C (212°F)
  • Boiling Point: >273°C (>523°F)
  • Flash Point: >110°C (>230°F)

Dynalene SF

Dynalene SF heat transfer fluid for open bath applications is a low toxic, low odor composition that demonstrates excellent thermal efficiency when operating at continual higher temperatures, without the high price of competitive alternatives.

    • Recommended Temperature Range: Room Temp. to 150°C (Room Temp. to 300°F)
    • Vapor Pressure: Negligible @ 100°C (212°F); <0.1 psia @ 150°C (300°F)
    • Boiling Point: >330°C (>627°F)
    • Flash Point: >180°C (>355°F)

Dynalene HT

Dynalene HT heat transfer fluid for open bath applications meet all of the desired thermo-physical and environmental qualities for high temperature processes. Non-corrosivity and high stability combine to make Dynalene HT fluid the ideal candidate for long-term efficient operation.

  • Recommended Temperature Range: Room Temp. to 177°C (Room Temp. to 350°F)
  • Vapor Pressure: Negligible @ 100°C (212°F); 0.02 psia @ 180°C (356°F)
  • Boiling Point: >385°C (>725°F)
  • Flash Point: >200°C (>392°F)

Dynalene 600

Dynalene 600 heat transfer fluid for open bath applications provide the superior endurance against waxing and polymerization when high operating temperatures are required. Dynalene 600, a silicone-derived fluid, is designed to safely maintain the highest flash point and lowest vapor pressure with minimal oxidation.

  • Recommended Temperature Range: 70°C to 288°C (158°F to 550°F)
  • Vapor Pressure: <0.02 psia @ 150°C (300°F); ~0.05 psia @ 204°C (400°F)
  • Boiling Point: >315°C (>600°F)
  • Flash Point: 315°C (600°F)

Recommended temperature ranges differ for closed systems
** Dynalene open bath fluids are available in 1, 5 , and 55 gallon containers or bulk transport. Typical properties and safety data on this document are not to be construed as specifications.

Type here to search

Order Kit & Test

Pre-labeled 100 mL Sampling Kit (with SDS) from Dynalene Labs

Kit Includes: Leak-proof 100 mL sample bottle, branded return mailer box with absorbent pouch, SDS & chain-of-custody card, and prepaid return shipping label. Placeholder Image and Text

Great! We’ve received your request.

Dynalene Labs · Whitehall, PA

Example Advanced Fluid Analysis Report

Fluid: Dynalene PG (35% Vol)  |  Sample Volume: 100 mL  |  Status: ACTION REQUIRED — Remediation Recommended
Diagnostic Category Analytes Measured (ppm) Sample Results (ppm) Assessment
Corrosion Products (ICP-OES) Fe, Al, Cu, Pb, Sn, Ag, Zn Fe: 18.4 ppm, Cu: 6.2 ppm, Al/Pb/Sn/Ag/Zn: < 0.5 ppm Elevated Fe & Cu
Contaminants (IC / ICP) Ca, Mg, Si, B, Mo, Na, SO₄²⁻, Cl⁻, NO₃⁻ Cl⁻: 92 ppm, Ca: 28 ppm, Mg: 9 ppm, SO₄²⁻: 34 ppm Hard Make-Up Water Ingress
Glycol Breakdown Products (IC) Glycolate, Formate, Acetate, Oxalate Glycolate: 310 ppm, Formate: 85 ppm, Acetate: 22 ppm, Oxalate: < 5 ppm Moderate Thermal Oxidation

Dynalene Engineering Recommendation: Elevated chloride (92 ppm) and hardness ions indicate un-deionized make-up water top-offs, while glycolate/formate organic acids have begun consuming reserve alkalinity and mobilizing iron/copper. Proactive Fix: Install an in-line / side-stream Dynalene CRS Series Ion Exchange unit with DYS 5 µm Filtration to strip chlorides and organic acids, then dose with custom Dynalene PG Inhibitor Booster.

Dynalene Labs · Whitehall, PA

Example Basic Fluid Analysis Report

Fluid: Dynalene PG (40% Vol)  |  Sample Volume: 100 mL  |  Status: PASS — Healthy
Test Parameter ASTM / Method Sample Result Target Specification Assessment
Appearance Visual Inspection Clear, fluorescent yellow, free of sediment Clear, free of suspended solids Normal
Fluid Concentration (Density & Refractive Index) ASTM D3321 / D5931 39.5% Volume PG (Freeze Pt: -21°C / -6°F) 40.0% ± 2.0% Volume Within Spec
pH Level (25°C) ASTM D1287 9.1 8.5 – 10.0 Optimal
Electrical Conductivity Conductivity Meter 2.84 mS/cm 2.50 – 3.50 mS/cm Normal
Inhibitor Package Health (Reserve Alkalinity) ASTM D1121 11.8 mL (96% active inhibitor remaining) ≥ 9.0 mL Passivated

Dynalene Engineering Recommendation: Fluid concentration, pH, conductivity, and corrosion inhibitor levels are all within optimal specification. No glycol adjustment or re-inhibition required at this time. Next routine Basic Testing checkup recommended in 6 months (semi-annual schedule)

Pre-Labeled 100 mL Sampling Kit: Includes a leak-proof 100 mL sample bottle, branded return mailer box with absorbent pouch, SDS & chain-of-custody card, and prepaid return shipping label.

Talk to an Engineer

Discuss test results, inhibitor boosters & in-line hardware

Great! We’ve received your request.

Program Inquiry

Dynalene Promise, Dynalene Protect & On-Demand Testing

Great! We’ve received your request.

Program Inquiry

Dynalene Promise, Dynalene Protect & On-Demand Testing

Great! We’ve received your request.

Submit Fluid Sample

Send your coolant sample to Dynalene Labs

Great! We’ve received your request.

⚙️ Talk to an Engineer

Custom solutions for your application

Great! We’ve received your request.

⚡ Quick Quote

We'll respond as soon as possible

Great! We’ve received your request.