Whether you need to maintain ultra-low conductivity, remove specific contaminants, or generate high-purity DI water, Dynalene has an ion exchange solution — backed by 30+ years of heat transfer fluid expertise.

IC Series

Low Conductivity Ion Exchange Cartridges

Maintains electrical conductivity <5 µS/cm in glycol-water coolants and heat transfer fluids

The IC Series mixed-bed ion exchange cartridges contain high-capacity resin media that captures ionic contaminants (Na⁺, Ca²⁺, Mg²⁺, Cl⁻, SO₄²⁻) as coolant flows through, preventing electrical conductivity rise that can cause leakage currents, corrosion, and equipment damage. Compatible with low-conductivity glycol-water blends and Dynalene heat transfer coolant products. Available in six sizes with FNPT or barbed connections.

Features

Applications

CR Series

Contamination Removal Ion Exchange Cartridges

Selectively removes specific ionic contaminants from process fluids and coolants

The CR Series uses targeted ion exchange resin formulations to remove specific contaminants — heavy metals, anions, or cations — without full demineralization. Ideal for industrial HTF loops, process cooling systems, and applications where selective ion removal is required to restore fluid specification compliance. Compatible with water-based and glycol-based fluids.

Features

Applications

DYI Series

Laboratory & Industrial Scale Deionization Systems

Provides maximum ion removal in water — from 1 to 40 GPM for medical, food processing, chemical and semiconductor applications

Dynalene DYI series deionization systems are designed and tested for maximum ion removal in water, ranging from small laboratory scale (1–10 GPM) to large industrial scale applications (up to 40 GPM). These systems are easy to install, can be wall-mounted or bought with a stand, and are ideal for making DI water on-site to be blended with glycol to make a glycol-water solution.

Features

Applications


Where It Works

Applications

Dynalene ion exchange cartridges are engineered for any closed-loop thermal system where ionic contamination raises electrical conductivity and risks equipment damage.

EV Battery Cooling (BTMS)

Maintains low electrical conductivity in battery thermal management loops. High-voltage EV systems (400V/800V) require coolant conductivity <5 µS/cm to prevent leakage currents and protect electronics.

IC Series

H

Hydrogen / Fuel Cell Cooling

Dynalene FC coolant paired with IC Series cartridges delivers a validated, matched fluid-filter solution for PEM fuel cell cooling loops requiring conductivity <1 µS/cm.

IC Series

30+

Data Center / CDU Cooling

Maintains low electrical conductivity in battery thermal management loops. High-voltage EV systems (400V/800V) require coolant conductivity <5 µS/cm to prevent leakage currents and protect electronics.

IC Series

Electronics & Laser Cooling

Keeps deionized or low-conductivity glycol coolants clean in precision electronics cooling, laser chiller loops, and computer cooling systems where conductivity spikes cause immediate equipment failure

IC Series

Contamination Removal

Selectively removes specific ionic contaminants — chlorides, sulfates, heavy metals (Mo, Se, As), and calcium/magnesium — from industrial process fluids and coolants.

CR Series

Deionization & Water Prep

Creates high-purity deionized water on-site for medical, semiconductor, and food processing applications, or for proper dilution of glycol heat transfer fluids.

DYI Series

Videos

See It In Action

Watch product overviews, installation walkthroughs, and real-world application demonstrations for Dynalene ion exchange systems.

IC Series Product Overview

Cartridge Installation & Replacement Guide

DYI Series: On-Site DI Water Generation


Why Dynalene

The Only Matched Fluid + Filter Solution

No other supplier in North America manufacturers both the heat transfer fluid and the ion exchange filter system designed to maintain it.

Fluid + Filter Integration

Matched IX cartridge grade, size, and interval for your exact fluid chemistry.

In-House Fluid Analysis Lab

Send a sample — we measure conductivity, ion load, pH, and prescribe the fix.

30+ Years of HTF Expertise

Three decades of fluid chemistry expertise no pure resin supplier can match.

Custom Engineering Available

Custom flow rates, connections, housings, and resin blends for OEM applications.

Direct E-Commerce

Order online for standard products without waiting for quote.

Fuel Cell & Hydrogen Ready

Dynalene FC + IC Series: the only validated matched system from one supplier.

Get Started

How Can We Help?

Quick Quote

Need pricing for IC, CR, or DYI Series products? Send us your flow rate, fluid type, and system volume — we'll respond as soon as possible.

Custom Solutions

Standard sizes don't fit? We engineer custom cartridge housings, resin blends, flow rates, and connections for OEM, industrial, and high-volume applications.

Submit Fluid Sample

Send a used coolant sample to Dynalene Labs. We test conductivity, ion load, pH, and degradation markers — then prescribe the exact cartridge and interval.

Type here to search

⚡ Quick Quote

We'll respond as soon as possible

Great! We’ve received your request.

⚙️ Talk to an Engineer

Custom solutions for your application

Great! We’ve received your request.

🧪 Submit Fluid Sample

Send your coolant sample to Dynalene Labs

Great! We’ve received your request.